Skip to content

Pipe clamp insert with PVC coating

-ISO- Csőbilincs-PVC

Use

In refrigeration / industrial refrigeration systems – fixing, vapour diffusion proofing

Raw material

In refrigeration / industrial refrigeration systems – fixing, vapour diffusion proofing

Packaging

With or without clamp

Length

Inner diameter

Depending on the pipe thickness, the 2, 3 or more components of the high load-bearing interlocking pipe clamp insert segment are mechanically strong, and provide adequate thermal insulation

for any pipe size. The pipe clamp insert consists of two semicircular parts made of polyurethane foam. The two half rings are covered with ALU tape, the ends of which are self-adhesive and covered with a protective film. The pipe clamp insert segment and the ALU coating form a strong water and vapour barrier layer. The finished pipe clamp insert has good heat retention properties, making it ideal for the thermal insulation of pipes (both cooling and heating). Our pipe clamp inserts are mainly used in the construction and petrochemical industries where a high degree of insulation is required. The inner diameter of the pipe clamp insert is the same as the outer diameter of the pipe on which it will be installed. The outer diameter of the product is the same as the outer diameter of the pipe insulated with pipe shells or plates, and matches the inner diameter of the supporting metal clamp.

Specification

PropertyValue
Temperature range-45 and 105ºC between
Processing temperatureabove 10ºC
Shelf life 1 year (above 10ºC)
Vapour diffusion resistance μ > 7000
Widthinner ø <114 mm - 50mm
inner ø >= 114 mm - 100mm
Colourblack
Fire resistanceB2 (according to DIN 4102)
Toleranceinner +/-0.5 mm;
outer +/- 1 mm
PU foam substrate 80/120/145 kg/m³

Inch sizes

DescriptionTypeSupport Inner Diameter (inch)Support Wall Thickness (inch)Support Length (inch)Support Outside Diameter (inch)
0.84 inch ID 1/2 inch wall 0,866 0,512 2,0 1,9
1.10 inch ID 1/2 inch wall 1,1 0,5125 2,0 2,1
1.66 inch ID 1/2 inch wall 1,66 0,53 2,0 2,7
1.875 inch ID 1/2 inch wall 1,89 0,53 2,0 2,9
2.35 inch ID 1/2 inch wall 2,35 0,55 2,03,5
2.5 inch ID 3/4 inch wall 2,510,762,04,0
3 inch ID 3/4 inch wall 2,990,762,04,5
3.5 inch ID 3/4 inch wall 3,500,762,05,0
4.25 inch ID 3/4 inch wall 4,250,804,05,9
4.50 inch ID 3/4 inch wall 4,500,804,06,1
5.25 inch ID 3/4 inch wall 5,240,804,06,8
-ISO- Csőbilincs- Alu-Foam

Pipe clamp insert with ALU coating

Use

Cooling/heating systems, fastening technology

Raw material

Polyurethane foam, ALU coating

Available options

With or without clamp

Length

Inner diameter

Depending on the pipe thickness, the 2, 3 or more components of the high load-bearing interlocking pipe clamp insert segment are mechanically strong, and provide adequate thermal insulation for any pipe size. The pipe clamp insert consists of two semicircular parts made of polyurethane foam. The two half rings are covered with ALU tape, the ends of which are self-adhesive and covered with a protective film. The pipe clamp insert segment and the ALU coating form a strong water and vapour barrier layer. The finished pipe clamp insert has good heat retention properties, making it ideal for the thermal insulation of pipes (both cooling and heating). Our pipe clamp inserts are mainly used in the construction and petrochemical industries where a high degree of insulation is required. The inner diameter of the pipe clamp insert is the same as the outer diameter of the pipe on which it will be installed. The outer diameter of the product is the same as the outer diameter of the pipe insulated with pipe shells or plates, and matches the inner diameter of the supporting metal clamp.

Specification

PropertyValue
Temperature rangebetween -45 and 120ºC
Processing temperatureabove 10ºC
Shelf life 1 year (above 10ºC)
Vapour diffusion resistance μ > 7000
Widthinner ø <114 mm - 75mm
inner ø >= 114 mm - 100mm
Colourgrey
Fire resistanceB2 (according to DIN 4102)
Toleranceinner +/-0,5 mm;
outer +/- 1 mm
PU foam substrate 80/120/145 kg/m³

Inch sizes

DescriptionTypeSupport Inner Diameter (inch)Support Wall Thickness (inch)Support Length (inch)Support Outside Diameter (inch)
0.84 inch ID 1/2 inch wall 0,866 0,512 2,0 1,9
1.10 inch ID 1/2 inch wall 1,1 0,5125 2,0 2,1
1.66 inch ID 1/2 inch wall 1,66 0,53 2,0 2,7
1.875 inch ID 1/2 inch wall 1,89 0,53 2,0 2,9
2.35 inch ID 1/2 inch wall 2,35 0,55 2,03,5
2.5 inch ID 3/4 inch wall 2,510,762,04,0
3 inch ID 3/4 inch wall 2,990,762,04,5
3.5 inch ID 3/4 inch wall 3,500,762,05,0
4.25 inch ID 3/4 inch wall 4,250,804,05,9
4.50 inch ID 3/4 inch wall 4,500,804,06,1
5.25 inch ID 3/4 inch wall 5,240,804,06,8

Pipe shell

-ISO- Csőhéj-_ALU-Foam_0001

Use

As insulating material for cooling/heating systems, cold/hot process systems.

Raw material

Polyurethane foam, Alu and Al-clad.

Thickness

Depending on the pipe thickness, 2, 3 or more interlocking segments of high load-bearing pipe shell segments are mechanically strong, and provide adequate thermal insulation for any pipe size. The interlocking pipe shells are originally laminated with aluminium foil, but can also be ordered without it. The finished pipe shell has good heat retention properties, the polyurethane foam and the

ALU coating prevents the formation of condensation between the pipe and the shell. Considering the advantages of the base material, their application can effectively reduce heat loss.

Specification

PropertyValue
Temperature rangebetween -45 and 105 ºC
Processing temperatureabove 10 ºC
Shelf life 1 year (above 10 ºC)
Vapourdiffusion resistance0.03g/qm/24 according to DIN 53122
Length100 cm
Colourblack
Fire resistanceB2 (according to DIN 4102)
Toleranceinner +/-0.5 mm;
outer +/- 1 mm
PU foam substrate 32/80/120 kg/m³

Thermosetting, high performance insulating materials

isocyro_logo

PU rigid foam

-200°C - +120°C

  • Raw density EN 1602: 38 – 42 kg/m³,

     

  • Thermal  conductivity  at application temperature 10 °C  EN 14308: [0.027] [0.026] [0.025] W/(m∙K)

isopir_logo

PU rigid foam

-80°C - +200°C

For short periods up to +250°C

  • Raw density (EN 1602): 37 – 42 kg/m³

  • Monitored limit (fresh value) at 10 °C mean temperature EN 12667: 0.021 W/(m∙K)

  • At 10 °C application temperature EN 13165 / EN14308: [0.027] [0.026] [0.025] W/(m∙K)

  • Designation (EU) [EN 13165] PU-EN 13165-T2-DS(70,90) 3-DS(-20,-) 2-CS(10\Y) 250-TR150

  • Designation (EU) [EN 14308] PU-EN 13165-T2-DS(70,90) 3-DS(-20,-) 2-CS(10\Y) 250-TR150

Supplementary fittings

Use

Industrial refrigeration, cooling and air conditioning.

Dimensions

Wit diameter and wall thickness according to request.

Available option

Bare, alu-clad, mesh-alu.

"Tee"

Elbow 45°/90°

Reducer

Contact us for orders and more information!